Installation Dimensions | 108 × 75.3 ×33 mm | |
Input power | 24 ~ 120V DC or 20 ~ 90V AC | |
Current output (peak) | 2.4 ~ 7.2A | |
Adaptive motor | Two-phase stepper motor | |
Control mode | Pulse+direction (default), dual pulse | |
Communication interface | TTL serial port | |
Digital signal | Input signal | Pulse, direction, enable signals: Opto-isolator; support 5~24V signals; maximum frequency 250Khz |
Output signal | Alarm output: collector open circuit; opto-isolator; maximum output 100mA@30V; | |
Current tap position | Dial setting | 2.4、3.1、3.8、4.5、5.2、5.8、6.5、7.2 A |
Subdivided tap position | Dial setting | 200、400、800、1600、3200、6400、12800、25600、1000、2000、4000、5000、6000、8000、10000、20000 |
Recommended service environment | Temperature | 0 ~ +55 ℃ |
Humidity | 0~ 90%RH below | |
Altitude | 1000 m below | |
environment | No corrosive gases or dust. | |
The product shall not come in contact with water and oil. | ||
Dielectric strength | AC1.5KV between ground wires, capable of withstanding voltage for 1 minute | |
Protection grade | IP20 | |
Weight | 0.3KG |